Feel the packing gland be careful of the rotating shaft to see if the packing gland is too hot or uneven which will result in damage to the pump shaft.
Fire pump packing.
Replace worn shaft sleeve if needed.
Waterous fire pump packing cmu 1993 up wtrs.
We also offer kits from patterson and fair banks please contact us with your pump information for purchasing.
Peerless fire pump installations ul listed ulc listed or fm approved deliver superior fire protection to facilities worldwide.
263 43 0 add to cart.
If it is a horizontal split case there will be six rings of packing on both sides of the shaft and in order to keep the shaft lubricated water needs to drip past the shaft to keep it lubricated.
You ll be confident that your system is ready to operate with real time monitoring and the added benefit of alerts and alarms notifications that you can configure.
If you have any questions about replacing fire pump packing or would prefer we perform the service for you simply pick up the phone and call us at 302 652 4722.
Waterous mechanical seal kit.
Never use anti seize or any metallic based compound on the pump packing.
The packing gland should be placed on top of the packing.
Hale zm packing kit.
Thoroughly clean and inspect the stuffing box.
Most fire pumps will have six rings of packing.
Gain system design advantages by leveraging our expertise in evolving standards and local fire codes.
Packing adjustment will be more frequent at first.
Pentair aurora s commitment to fire suppression system performance and quality service goes beyond just 100 years of perfecting fire pump design.
Peerless fireconnect allows you to access complete fire pump system information 24 7 anytime and anywhere via your smartphone tablet laptop or desktop.
Stocking packing for your waterous hale darley c entrifugal fire pump.
When people such as maintenance crews etc.
Centrifugal fire pump packing.
Field tested products are designed for reliability and longevity and include a broad selection of pumps drives controls baseplates and accessories.
166 32 0 add to cart.
Tighten down the followers.
Repacking and regular maintenance is import for protecting your building as well as preventing expensive repairs later.
Coat each new packing ring with pak lube go jo or some type of liquid soap.
Products 6 sort by.
Adjust the followers one flat or of a turn every 30 minutes or until the leakage is controlled.
Post navigation fire pump parts accessories availability hubbell launches a new line of metron fire pump controllers.
Posted in fire pumps general information and tagged extend pump service life packing gland adjustments on april 8 2016 by admin.
But as the pump and packing start to set in you can expect a couple years of consistent and reliable service.