Click thumbnail to view image.
Fire damper types.
Rated static fire dampers.
Used when airflow or velocity in the duct is a concern.
When a rise in temperature occurs the fire damper.
Static fire damper 3 hr ul rated.
Aire technologies 05 series 3 hr.
When the damper or damper assembly exceeds either 48 in width or 60 in height the retaining angles should not be less than 1 1 2 x 1 1 2 x 1 8 thick and should be attached to the sleeve using 20 1 4 x 3 4 round head stove bolts at 8 on c.
14 x 3 4 sheet metal screws at the same spacing.
Fire dampers are installed in fire walls fire barriers fire partitions and horizontal assemblies.
Applications where fans shut down.
Type a dampers are the easiest and fastest type to install and are mostly used in low pressure part of duct systems up to 2 w c.
Fire damper designing buildings wiki share your construction industry knowledge.
The dampers are designed for operation in the vertical or horizontal position with blades running horizontal.
Type a b c.
1 long welds or no.
Fire dampers are devices designed to impede the spread of fire through walls floors and partitions.
The type c fire damper is generally used where velocities are medium to high and free area is a consideration.
Fire smoke dampers are similar to fire dampers in fire resistance rating and also prevent the spread of smoke inside the ducts.
Type c dampers can be ordered with low pressure less than 3 w c medium high pressure from 3 w c.
The dampers are to be installed square and free from twisting or racking.
Fire dampers are passive fire protection products used in heating ventilation and air conditioning hvac ducts to prevent the spread of fire inside the ductwork through fire resistance rated walls and floors.
They work to help stop the spread of flame through your air ducts.
A fire damper closes once the temperature of the duct becomes high enough to melt the fusible link which holds it open.
This installation instruction applies to fire dampers static dynamic curtain single and multi blade types mounted in the plane of an ul approved fire partition.
Up to 10 w c or high pressure 10 w c pressure ratings.
The stack of blades in the fire damper frame is kept out of the air stream.
Fire dampers are ul555 tested and labeled devices installed in ducts and air transfer openings or air distribution systems designed to close upon the detection of heat.
Home fire dampers duct fire dampers static type duct fire damper.
The term fire damper is defined by approved document b fire safety volume 2 buildings other than dwellinghouses as a.