Making drafting pits and other pump testing methods obsolete.
Fire truck pump test trailer.
Our fire trailers are ready to use at a moment s notice when on a job site.
The draft commander 3000 mobile fire pump testing training unit allows you to perform a true pump test from draft with clean water.
Immediately after the 20 minute test run the pump for 5 minutes at its rated capacity at 165 psi.
5 minute dry vacuum test timed primer test 20 minute test at rated capacity and 150 psi 5 minute spurt overload test at rated capacity and 165 psi not required by iso but recommended by nfpa 10 minute test at 70 percent capacity and 200 psi.
In many cases when they get ready to run a pump test the primers don t work weis fire safety equipment manufactures the draft commander 3000 a draft tank with the means to bring pump test capabilities to a fire station or remote locations.
Testing ensures that your engine and fire pump are performing with the correct horsepower and pumping the correct amount of gpm.
Fire trailer system includes 2 heavy duty 3 500lb axles and springs 6 steel channel frame tank constructed with 10 gauge steel w baffling wiring is enclosed in steel tubing.
We test to the requirements of nfpa 1911 including the priming system test.
Whether you come to our facility or we come to yours our pump testing program is very popular with area departments.
Fire horse our line of brush trucks mini pumpers and support vehicles.
Numerous fire trucks in the field won t pass the pump test weis said.
Randco s rugged design handles the logging operations tough conditions.
Run the pump for 10 minutes at 70 capacity and 200 psi.
The nfpa requires this test for pumps rated for over 750 gpm.
Fire pumps on apparatus shall be service tested in accordance with the applicable requirements of nfpa 1911.
Check out our line of trucks and list of options.
An annual pump test is actually a series of timed tests as follows.
We take the hassle out of required annual fire pump tests.
If you don t see what you re looking for our custom trucks can be specially designed to fit your needs.
Our program helps maintain critical pump performance.
Pump testing can now be done at your fire station.
Run the pump for 10 more minutes at 50 capacity and 250 psi.