From the 2016 edition of nfpa 13.
Fire pump room signage requirements.
Section 6 6 4 of nfpa 13 stipulates sign requirements for all control drain venting and test connection valves while section 8 16 1 1 expands on the guidance for control valves.
6mm when located outside or as approved by the fire code official.
Section 10 1 2 5 2 has a requirement for electrical fire pumps systems when multiple pumps serve different areas or portions of the facility an appropriate sign must be conspicuously attached to each controller indicating the area zone or portion of the system served by that pump or pump controller.
Gaseous fire extinguishing systems 22.
High voltage installations 16.
And some local codes require riser rooms to house remote unit fire alarm panels connected to the master fire alarm panel in multi family residential occupancies.
Fire detectors remote indicators 14.
A fire pump room sign is a useful tool to help protect the health and safety of staff and is not a substitute for necessary protective measures for lessening or eliminating hazards.
Unless more stringent requirements apply lettering for signs required by this section shall have a minimum height of 2 inches 50.
The total head of a fire pump is the energy imparted to the liquid as it passes through the pump usually expressed in psi.
Fire control room 19.
A fire pump room sign has fdc messages for emergency response protocol and compliance.
Fire pump room sign brushed aluminum aluminum signs 3 5x8 the mont argent line 10.
6 6 4 identification of valves.
Fire indicator panel 13.
We at hpd signs nyc provide all fire pump signage water pump signage for you building.
Fire pump room no storage permitted sign photoluminescent glow in the dark sign photoluminescent aluminum signs 14x10 14.
Exit directional signs 12.
For fire pumps such as horizontal split case and vertical in line centrifugal pumps that are required to operate under net positive suction head the total head of a fire pump is calculated by adding the suction head city pressure to the.
Nfpa 20 provides for protection of the fire pump equipment as well as for personnel that need to access the fire pump equipment during a fire situation.
The letters shall be of a color that contrasts with the.
While nfpa 20 requires that access to the fire pump room be pre planned with the fire department it now requires that the location of the fire pump room also be pre planned.
Non required stairs ramps escalators 21.
Most fire sprinkler system valves must be identified with metal or rigid plastic signs.
Fire p ump p ressures.