This detailed fire door inspection checklist can be used to survey the overall condition of fire doors.
Fire door checklist form.
To help you implement the advice you are given during the week checkmate fire has compiled a downloadable fire door inspection checklist.
Fire door assembly inspection checklist the 2007 and 2010 editions of nfpa 80 standard for fire do ors and other opening protectives section 5 2 inspections require all fire doors to be inspect ed not less than annually.
Our fire smoke door experts will provide a thorough inspection of all the doors in the building to ensure they are safe and complying with the nfpa code and prepare a detailed report on the condition and function of the fire door on your facilities.
Door components need to be inspected and tested.
Inspect and test all rated fire door assemblies for items listed below and identify issues or concerns.
Signs should be fitted on all non domestic fire doors and be visible at eye level.
If these have been tampered with or.
Labels every fire door should display a bwf certifire fire door scheme label usually found on the top edge of the door.
Building information on fire certificate activation pdf 120kb checklist for fire protection systems and fire safety measures.
Leaf the door leaf should sit flush with the door stop and without any distortion.
For reference only not to be submitted when making an application for fire certificate doc 408 kb fire certificate forms for first time application doc 40kb fire certificate forms for renewal application doc.
Doors with fire protection rating labels.
Annotate images taken and generate reports on the spot using your mobile device.
We are certified to perform detailed 13 points fire doors inspection.
Bs5499 lay down standards for the size and siting of fire door safety signs.
Fire doors should be regularly inspected for damage that may prevent the door from performing in the event of a fire.
All issues should be corrected immediately.
Any issues should be fixed as soon as possible using compatible correct fire rated components.
A visual inspection is required before testing to identify any damaged or missing parts that might create a hazard during testing.
Nfpa 80 requires that all fire door assemblies be inspected and tested yearly.
Life safety code section 7 2 1 15 2 requires all fire and smoke doors to be inspected and tested annually including doors such as.
Fire door safety week 2018 which runs from september 24th to 30th is designed to promote awareness of the importance of choosing the right fire doors and ensuring they are properly installed and maintained.
This may form part of the risk assessment for the building.